-40%

60,000 BTU 5 Zone Ductless Mini Split Air Conditioner - Heat Pump: 12k x 5 BTU

$ 2119.05

Availability: 12 in stock
  • Control Style: Digital
  • Item must be returned within: 30 Days
  • Model: T321Q-H263 12+12+12+12+12
  • Brand: Thermocore
  • Size: 5 tons
  • Restocking Fee: 15%
  • Type: Split System
  • Number of Cool Speeds: Variable
  • Return shipping will be paid by: Buyer
  • All returns accepted: Returns Accepted
  • Number of Fan Motors: 1
  • Energy Star: Compliant
  • Features: Ductless
  • Timer Control: 24 Hours
  • Capacity: 58,100-72,000 BTUh
  • Power Phase: 1 Phase
  • Area Covered: Greater Than 1000 sq ft
  • BTU Cooling Rating: 25000 BTU or Greater
  • Compressor Type: Rotary & Impeller
  • Number of Compressors: 1
  • Number of Zones: 5 or More
  • Condition: New
  • Blower Motor Speed: Variable Speed
  • MPN: Does Not Apply
  • Items Included: Remote Control
  • SEER Rating: 21
  • Color: White
  • Voltage: 208/230 V
  • Refund will be given as: Money back or replacement (buyer's choice)
  • Power Source: Corded Electric

    Description

    Thermocore 60000 BTU AC-Heat 21 SEER
    60000 BTU Quint Zone Energy Star Mini Split AC
    21 SEER Efficiency w/ Heat Pump Technology
    With a 60000 BTU total Cool / Heat Capacity, the
    Thermocore T321Q-H263-12+12+12+12+12 Energy Star mini split AC
    can cool or heat 5 separate zones of 12000 BTU for a total coverage area of 3000 ft² (600 ft² x 5).  Most Energy Efficient Quint-Zone series in the market! - A 21 SEER coupled with Inverter technology provides the benefits of low operation temps as well as maximum energy efficiency.
    1 Year Part - 5 Year Compressor Warranty.
    Technical Data:
    System Includes:
    60,000 BTU
    INVERTER
    Cooling Capacity (12k x 5)
    60,000 BTU INVERTER Heat Pump Capacity (12k x 5)
    21 SEER - 10.4 HSPF
    - AHRI / ENERGY STAR Eligible
    *
    Pre-Charged with ECO-Friendly R410A
    1 Year Parts - 5 Year Compressor Warranty
    View Details >
    Indoor Unit - Air Handler.
    Outdoor Unit - Condenser of 44000-58000 BTUs
    Digital Multi-function LCD Remote Control.
    Product and Installation Manual. >>>
    ** Rated Capacity of Condenser will be less than actual delivered capacity in above configuration. Rated Capacity is not the same as Maximum Capacity.
    Click here for Capacity Calculation Table.   SEER is based on using with heads packaged with system.  Energy label will be 17.8-21.5 **
    Top Line Features:
    21 SEER - 10.4 HSPF
    - ENERGY STAR
    Most Energy Efficient Quint-Zone Series on Market
    Dry-Mode removes moisture w/o affecting temp
    Cross Flow Technology reduces noise output
    Compatible with over 5 Filtration medias
    Freon Leak Detection > Notification system
    Low Ambient Temperature Operation (5° F)
    Two-direction Air vane Evenly Distributes Air
    Restart IC: Settings restored Following Outage
    Follow-Me Function tracks Remote Location
    ** Installation Lineset Sold Seperately: Available in 15-75ft Lengths.
    Contact us for customized package or
    Click here
    to Purchase.
    The particle filter or “pre-filter” removes dust and other air-borne pathogens before pushing the air through additional filtration medias and the refrigeration coil array.  This filter is washable and comes factory installed with every ductless air conditioner system.
    The open channel construction of the 3M High Air Flow (HAF) filter offers low initial airflow resistance, while its unique microstructure and electrostatic charge provides effective particle capture and retention. This translates into fewer filter change outs and reduced coil cleaning.
    CLICK TO PURCHASE >>>
    The Vitamin C Filtration media releases Vitamin C into the air which softens skin and reduces stress among other therapeutic benefits.  A good choice for those wanting to add some invigoration to their indoor air environment.  Filter lasts over 2 years.
    CLICK TO PURCHASE >>>
    The anti-microbial effect of silver ionic technology kills allergy causing bacteria by destroying the inner configuration elements of the cell body. The nano-silver attached to the filter screen constantly releases silver ions which directly eliminates and prohibits bacteria from replicating.
    CLICK TO PURCHASE >>>
    Eliminates odors such as ammonia and deactivates harmful chemicals has such as formaldehyde.  By forming positive positions on the filter surface, Electrostatic Fiber traps small dust particles, smoke and pet dander to prevent allergic reactions and neutralize odor in the air.
    CLICK TO PURCHASE >>>
    Indoor Unit (evaporator) specs CLICK FOR FULL SPEC SHEET
    Model Number
    T3-OS212-EW
    Capacity
    12000 BTU
    Air Flow (Hi/M/Lo)
    440/380/260 cfm
    Power Supply
    230 V / 60 Hz / 1Ph
    Noise Output (Hi/M/Lo)
    36/27/23 dBA
    Liquid / Gas
    1/4" x 1/2"
    Weight
    18.1 lbs
    Dimensions (W x D x H)
    31.6" × 7.5" × 11.7" in.
    VIEW FULL AIR HANDLER SPECIFICATION SHEET >>>
    Outdoor Unit (condenser) specs CLICK FOR FULL SPEC SHEET
    Model Number
    T321Q-H263
    Compressor Brand
    MITSUBISHI or TOSHIBA-GMCC
    Rated Capacity
    48000 BTU
    Maximum AH Capacity
    63000 BTU
    Air Flow
    4470 CFM
    Power Supply
    230 V / 60 Hz / 1Ph
    Input Power
    1900W - 6440W
    SEER
    21.5 (IF USED WITH T3 MOUNT)
    EER
    11.6
    HSPF4
    10.4
    Sound Level
    64 dBA
    Moisture Removal
    3.9 L/hr
    Operating Temp Range
    5 - 122 F (cool and heat)
    Refrigerant
    R410A / 162oz Charge
    Liquid / Gas
    1/4" x 3/8" (3) - 1/4" x 1/2" (2)
    Max Lineset Length (1 zone)
    98 ft
    Max Lineset Length (all zones)
    246 ft
    Weight
    224 lbs
    Dimensions (W x D x H)
    37.5 × 16.5 × 52.5 inches
    VIEW FULL CONDENSER SPECIFICATION SHEET >>>
    CLICK TO VIEW COMBINATION CALCULATION TABLE >>>
    WHAT IS DC INVERTER?
    DC Inverter Air Conditioners are the ultimate cooling technology of the HVAC field. They are called "DC inverter" because the alternative current (AC) is converted to Direct Current (DC) then, direct current inverted back to Alternative current with desired frequency. The current supplied through the wall outlet has fixed frequency which is 60 Hertz. Different frequencies supplied to the compressor will result in different running speeds of the compressor. Inverter control systems use Pulse Amplitude Modulation (PAM) that is the most advanced and energy efficient method of inverting the current. DC Inverter AC's bear special compressors that their speed could be changed by increasing or decreasing the frequency of the supplied power. Therefore, unlike conventional split Air Conditioners Pumps which cycle between on and off repeatedly, the DC Inverter control system will monitor the room temperature and adjust the compressor speed automatically.
    Conventional compressors turn on and off to maintain the room temperature at desired level. This will result compressor to draw tremendous energy each time it starts up. This will also reduce the life-span of the compressor and other components that are turning on and off. Once a conventional system is running, it runs at its maximum speed, consuming the maximum amount of energy in order to produce the maximum of cooling to maintain the desired temperature. The system will then cycle between on and off in an effort to maintain this temperature. When a DC Inverter compressor initially starts up, it runs with a higher speed to bring the room temperature to desired level rapidly, Once the set temperature is reached, it slows down and adjust its capacity just to counter the heat loss or heat gain of the building. Constant temperature is maintained.
    BASIC OVERVIEW:
    The indoor unit is hung like a picture frame approximately 6 - 8 feet above the floor usually on an exterior wall. A 2-3 inch hole must be made behind the indoor unit in the exterior wall to run the refrigerant copper tubing, electrical wires and the condensate drain to the outside unit. The indoor unit and outdoor unit are connected to each other by means of refrigerant copper tubing and electrical cables. The condensing unit comes pre-charged with R410A Freon however, procedures such as conducting leak tests etc. are still important steps in ensuring proper functioning of a split AC. *Although installation may seem easy to some, certain tools and experience is necessary to complete setup of a mini split*It is highly advised a certified HVAC technician complete installation to be eligible for warranty. See warranty details below >
    *5 Year Compressor - 1 Year on all other Parts*
    Registration card will be sent with unit, this card should be completed by an HVAC technician (installer).  Installation of a mini split must be completed by a licensed HVAC (Heating, ventilating, & air conditioning) company to ensure any issues encountered in the future are not due to improper installation / workmanship.  Even though mini split setup is below the expertise requirements of central AC systems, these are not "plug-n-play" units that can be properly installed without certain tools any prior HVAC - electrical knowledge.   The installation includes electrical, gas, and refrigerant connections and generally regulated by a multiple sets of laws, codes and guidelines, at the federal, state and local levels. The failure to properly install HVAC equipment can raise personal safety and performance concerns. Warranty service - troubleshooting is provided through the contractor / installer and will be upheld as long as policies are observed.  Once a non-defective unit is installed by a HVAC company, chances of anything going wrong are very slim and almost all contractors will guarantee there workmanship and provide future service free of charge (installation warranty).  If it was determined that the unit is not functioning due to a defect and needs to be replaced, the part will be sent free of charge up to 1 year from date of purchase or 5 years for the compressor. If you receive a damaged or defective product, a replacement unit will be sent out Free of cost.  Damaged / Defective product will be picked up and a brand new exchange will be shipped out.
    1 YEAR PARTS WARRANTY CAN BE EXTENDED TO 2 YEARS FOR AN ADDITIONAL .00
    SHIPS TO TO BOTH UNITED STATES AND CANADIAN LOCATIONS!
    Our Thermocore systems ship via RL Carriers or similar LTL freight service out of Oak Park, Michigan and are palletized onto a single skid.  Transit time is usually between 4 to 6 business days from payment receipt depending on where you are geographically located.
    Please provide a contact phone# upon checkout
    (to be used for delivery purposes only).  SOMEBODY MUST BE ON SITE TO ACCEPT / SIGN FOR Order.  Failure to provide valid contact# will delay order.  System comes with Free shipping - this includes delivery to any location within the Continental United States. We will ship to Canadian locations but we need to quote separately - please contact our offices.  Additional freight for Canadian registries is usually around 0. (import and duties may apply).
    Condenser Ground Stand
    - Provides Flat even surface
    - Avoids debris obstruction
    Price:
    .00
    Click for more Info
    Lineset Extension (1/4 x 3/8)
    - Extend included 16 ft copper lineset to 25ft - 30ft - 40ft - 50ft
    Price:
    .00 > 4.00
    Click for more Info
    Condenser Bracket
    - Mount your condenser at any height on an outdoor sidewall
    Price:
    .00
    Click for more Info
    Micro-Pump II
    - Required when mounting air handler on Interior wall
    Price:
    2.00
    Click for more Info
    Electrical Wire Harness
    - 16/4 Electrical Wire Harness
    - For Extending Evap. Length
    Price:
    .85 / ft
    Click for more Info
    Additional Remote Controls
    - Spare remote controls for the T1 Series Ductless System
    Price:
    .00
    Click for more Info
    Filter Medias
    - Inserts into Filter Screen Slot
    - Choice of 4 Filtration Medias
    Price:
    .00 - .00
    Click for more Info
    Wired Thermostat
    - Permanently Hard Mounts
    - Controls Settings w/ Remote
    Price:
    .00
    Click for more Info
    Swap 1 Mount for Cassette:
    (+) 0
    Swap 2 Mount for Cassette:
    (+) 0
    Swap 3 Mount for Cassette:
    (+) 0
    Swap 4 Mount for Cassette:
    (+) 0
    Swap 5 Mount for Cassette:
    (+) 0
    * 9k heads do not come in cassette option - need to upgrade to 12k
    Swap 1 Mount for Susp. Ceiling:
    (+) 0
    Swap 2 Mount for Susp. Ceiling:
    (+) 0
    Swap 3 Mount for Susp. Ceiling:
    (+) 0
    Swap 4 Mount for Susp. Ceiling:
    (+) 0
    Swap 5 Mount for Susp. Ceiling:
    (+) 0
    Customize your system to meet your requirements - see below table for available output options:
    Tri-Zone Setup
    9k + 18k + 18k
    9k + 18k + 24k
    12k + 12k + 18k
    12k + 18k + 18k
    9k + 9k + 24k
    12k + 12k + 24k
    12k + 18k + 24k
    12k + 24k + 24k
    18k + 18k + 18k
    18k + 18k + 24k
    Quad-Zone Setup
    9k + 9k + 12k + 12k
    12k + 12k + 12k + 12k
    9k + 12k + 12k + 18k
    12k + 12k + 12k + 12k
    12k + 12k + 12k + 18k
    9k + 9k + 9k + 24k
    9k + 12k + 18k + 18k
    9k + 9k + 18k + 18k
    9k + 18k + 18k + 18k
    9k + 9k + 18k + 24k
    12k + 12k + 18k + 18k
    12k + 12k + 12k + 24k
    Quint-Zone Setup
    9k + 9k + 9k + 9k + [9/12/18/24]
    9k + 9k + 9k + 12k + [12/18]
    9k + 9k + 9k + 18k + 18k
    9k + 9k + 12k + 12k + [12/18]
    9k + 12k + 12k + 12k + 12k
    12k + 12k + 12k + 12k + 12k
    This system available in multiple air handler (zone) capacity combinations to meet the requirements of any application.  Air handlers are available in 9k, 12k, 18k and 24k outputs. Be advised, for arrangements where combined output of all heads exceeds rated capacity of condenser (54000 BTU's) - the total output will not exceed 54000's when all air handlers are running at full capacity simultaneously.  However, overated zones will draw required capacity from other zones either running at lower modes or areas that have reached thermostat settings to obtain rated output.  For example, with a 12k-12k-12k-12k+12k configuration, the total output will be along the lines of 11k-11k-11k-11k+11k when all zones are running on high/full settings at the same time.  However, once a zone obtains set temperature and/or operates at a lower setting, the capacity will bleed off into zone that needs the extra push to obtain the 12k-12k-12k-12k-12k yield.  See Combination Calculation Table